ENVIROSAFE SELF-SEALING SEWER COVER - INSTALLATION INSTRUCTIONS 1. Inspect for damage during shipment and handling. Components are tested for leaks prior to shipment. 2. Remove existing catch basin grate. 3. Clean all debris from existing catch basin grate flange. Surface should be dry and free of any oil, dirt 4. Surface preparation: Clean underside of the ESSCO Sewer Seal flange and the catch basin grate flange 5. Check for any obstructions along vertical walls in catch basin. 6. Apply two (2) continuous parallel beads of Dow Corning 739 Silastic sealant or equal around the 7. Place ESSCO Sewer Seal in catch basin and press in place to spread sealant and seal flange. Smooth out 8. Fill ESSCO Sewer Seal with water to top of overflow pipe. 9. Install the ESSCO Sewer Seal cap over the overflow pipe. 10. Replace the catch basin grate over the ESSCO Sewer Seal. Some grates types, other than flat, may Caution 1. Always inspect the ESSCO Sewer Seal for combustible gases and proper water level before any "Hot Work" is allowed. 2. If combustible gases are detected, remove the ESSCO Sewer Seal cap, flush with water, replace cap and 3. Type 304 stainless steel material has been selected, as the standard material of construction, for its |